NROs for multiple UNH messages within one EDIFACT interchange

$
0
0

Hi,

 

I am currently facing the problem to generate unique sequence numbers within an EDIFACT interchange that contains multiple messages (UMH). Inside the mapping I have populated the NRO according to guidelines by SAP within the UNH-0062 and UNT-0062 fields of the EDIFACT message. When I check the generated EDIFACT file I noticed that the sequence numbers for all UNH messages are the same:

 

UNB+UNOA:3+GLN-A:14+GLN-B:14+140904:1103+11'

UNH+15+ORDERS:D:96A:UN'

UNT+18+15'

UNH+15+ORDERS:D:96A:UN'

UNT+23+15'

UNH+15+ORDERS:D:96A:UN'

UNT+18+15'

UNZ+3+11'

 

Where I would have expected the following:

UNB+UNOA:3+GLN-A:14+GLN-B:14+140904:1103+11'

UNH+15+ORDERS:D:96A:UN'

UNT+18+15'

UNH+16+ORDERS:D:96A:UN'

UNT+23+16'

UNH+17+ORDERS:D:96A:UN'

UNT+18+17'

UNZ+3+11'

 

Setting the parameter multipleNumbersPerMessage to Yes inside the communication channel also does not help. This will produce the following:

UNB+UNOA:3+GLN-A:14+GLN-B:14+140904:1103+11'

UNH+15+ORDERS:D:96A:UN'

UNT+18+16'

UNH+17+ORDERS:D:96A:UN'

UNT+23+18'

UNH+19+ORDERS:D:96A:UN'

UNT+18+20'

UNZ+3+11'

 

Is there anyone out there who knows how to achieve this (per UNH message the same sequence number)?

 